2 resultados para CHEST PHYSIOTHERAPY

em DI-fusion - The institutional repository of Université Libre de Bruxelles


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Diagnosis of childhood active tuberculosis (aTB) or latent Mycobacterium tuberculosis (Mtb) infection (LTBI) remains a challenge, and replacement of tuberculin skin tests (TST) by commercialized interferon-gamma release assays (IGRA) is not currently recommended.Methods:266 children between 1 month and 15 years of age, 214 being at risk of recent Mtb infection and 51 being included as controls, were prospectively enrolled. According results of clinical evaluation, TST, chest X-Ray and microbiology, children were classified as non-infected, LTBI or aTB. Long-incubation time PPD-, ESAT-6-, and CFP-10-IGRA were performed and evaluated for their accuracy to correctly classify the children.Results:Whereas both TST and PPD-IGRA were suboptimal to detect aTB, combining CFP-10-IGRA with TST or with PPD-IGRA allowed us to detect all the children with aTB, with 96% specificity for children who were positive for CFP-10-IGRA. Moreover, combination of CFP-10- and PPD-IGRA also detected 96% of children classified as LTBI, but a strong IFN-γ response to CFP-10 (>500 pg/ml) was highly suggestive of aTB at least among children less than 3 years old.Conclusions:Long-incubation time CFP-10- and PPD-IGRA should help the clinicians to identify quickly aTB or LTBI in young children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.